{"id":4294,"date":"2020-10-22T10:59:11","date_gmt":"2020-10-22T10:59:11","guid":{"rendered":"http:\/\/www.inmesol.com\/blog\/?p=4294"},"modified":"2024-01-29T10:03:45","modified_gmt":"2024-01-29T10:03:45","slug":"single-generator-set-with-a-multitude-of-different-applications","status":"publish","type":"post","link":"https:\/\/www.inmesol.com\/fr\/blog\/single-generator-set-with-a-multitude-of-different-applications\/","title":{"rendered":"A single generator set with a MULTITUDE of different applications"},"content":{"rendered":"<h2>Inmesol has developed a new multifunctional unit for its MULTIPURPOSE generator sets<\/h2>\n<p>The <strong>generator set<\/strong> that is used in <strong>rental, public services, construction<\/strong> or other applications, in which the gen set must perform <strong>multiple functions<\/strong>, should be <strong>easy and safe<\/strong> to operate in order to adapt to the actual work that it must perform at any given time.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-4295\" src=\"\/wp-content\/uploads\/2020\/10\/a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"Inmesol has developed a new multifunctional unit for its MULTIPURPOSE generator sets\" width=\"750\" height=\"450\" title=\"\" srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/a-single-generator-set-with-a-multitude-of-different-applications.jpg 750w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/a-single-generator-set-with-a-multitude-of-different-applications-300x180.jpg 300w\" sizes=\"(max-width: 750px) 100vw, 750px\"><\/p>\n<p><strong>INMESOL <\/strong>has developed a new range of <strong>control units <\/strong>for <strong>multipurpose <\/strong>generator sets based on the <strong>DSE 8620 MKII <\/strong>or the <strong>DSE 8920<\/strong>, where <strong>the functions <\/strong>from <strong>DSE 8620MKII or DSE 8920 <\/strong>can be easily switched <strong>to DSE 8610 MKII or DSE 8910 functions <\/strong>from a single control unit.<\/p>\n<p><strong>Changing applications <\/strong>and from some <strong>features<\/strong> to others is very easy with the control unit\u2019s <strong>selectors and potentiometer<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4296 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/1_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"the control unit\u2019s selectors and potentiometer\" width=\"759\" height=\"220\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 759px; --smush-placeholder-aspect-ratio: 759\/220;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/1_a-single-generator-set-with-a-multitude-of-different-applications.jpg 759w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/1_a-single-generator-set-with-a-multitude-of-different-applications-300x87.jpg 300w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 759px) 100vw, 759px\"><\/p>\n<p><em><strong>Note: <\/strong>For any application and <strong>operation <\/strong>of the generator set, the <strong>OFF\/ON <\/strong>selector must be on the <strong>ON position (position I).<\/strong><\/em><\/p>\n<h2>Possible applications of a generator set(s) with a MULTIFUNCTION control unit<\/h2>\n<p>A generator set with a <strong>MULTIFUNCTION<\/strong> control unit can work in <strong>any of these applications<\/strong>:<\/p>\n<p><strong>DSE 8610 MKII<\/strong> Features<\/p>\n<h3 style=\"padding-left: 40px;\"><strong>1. Manual<\/strong> generator set in <strong>island mode<\/strong> with remote start up or <strong>external signal start up<\/strong>.<\/h3>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4297 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/2_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"Manual generator set in island mode with remote start up \" width=\"650\" height=\"480\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 650px; --smush-placeholder-aspect-ratio: 650\/480;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/2_a-single-generator-set-with-a-multitude-of-different-applications.jpg 650w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/2_a-single-generator-set-with-a-multitude-of-different-applications-300x222.jpg 300w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 650px) 100vw, 650px\"><\/p>\n<p>The operation of the manual generator set in <strong>island mode <\/strong>is the most <strong>basic <\/strong>configuration in the control unit, and used when there is <strong>no mains <\/strong>or other generator sets present. The generator set <strong>receives an external signal<\/strong>, which closes a <strong>contact<\/strong> and produces the <strong>start up<\/strong>. After a few seconds, the gen set parameters will be <strong>within <\/strong>the accepted levels, and the generator switch will close, thus <strong>powering <\/strong>the load. When the signal is <strong>removed<\/strong> the unit&rsquo;s circuit breaker <strong>opens <\/strong>and the engine <strong>stops <\/strong>after a period of cooling.<\/p>\n<h3 style=\"padding-left: 40px;\">2. Generator set in parallel with the mains by exporting a fixed power to the mains.<\/h3>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4298 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/3_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"Generator set in parallel with the mains by exporting a fixed power to the mains\" width=\"858\" height=\"386\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 858px; --smush-placeholder-aspect-ratio: 858\/386;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/3_a-single-generator-set-with-a-multitude-of-different-applications.jpg 858w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/3_a-single-generator-set-with-a-multitude-of-different-applications-300x135.jpg 300w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/3_a-single-generator-set-with-a-multitude-of-different-applications-768x346.jpg 768w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 858px) 100vw, 858px\"><\/p>\n<p>In this application, the generator set <strong>exports <\/strong>electric power to the mains, when it requires input.<\/p>\n<p>The generator set is connected to the mains and the <strong>parallel <\/strong>selector is switched to the ON position. The <strong>start up<\/strong> signal of the generator can be entered <strong>manually <\/strong>or by means of a <strong>remote signal<\/strong>.<\/p>\n<p>By starting the unit manually and, after a few seconds, pressing the <strong>Close gen set<\/strong> button, the unit synchronises with the mains and the circuit breaker closes.<\/p>\n<p>Initially, the generator set delivers a minimum power that will increase until reaching the power set with a potentiometer, the <strong>&lsquo;POWER&rsquo;.<\/strong><\/p>\n<p>Pressing the <strong>Mains<\/strong> control button, the power of the unit decreases until reaching a minimum power and then opens the circuit breaker. After a cooling period, the engine shall be stopped.<\/p>\n<p>If the unit is started through a remote signal, the same sequence that is manually performed will be automatically executed, as well as when the signal disappears.<\/p>\n<h3 style=\"padding-left: 40px;\">3. Generator set in sync with other generator sets with shared load.<\/h3>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4299 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/4_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"Generator set in sync with other generator sets with shared load\" width=\"858\" height=\"579\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 858px; --smush-placeholder-aspect-ratio: 858\/579;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/4_a-single-generator-set-with-a-multitude-of-different-applications.jpg 858w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/4_a-single-generator-set-with-a-multitude-of-different-applications-300x202.jpg 300w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/4_a-single-generator-set-with-a-multitude-of-different-applications-768x518.jpg 768w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 858px) 100vw, 858px\"><\/p>\n<p>This occurs when a load is shared by <strong>several generator sets <\/strong>who are <strong>mutually synchronised<\/strong> and each assumes an established load distribution, starting and stopping according to the load demand. Gen sets can be configured to alternate their service.<\/p>\n<p>With the same basic configuration in parallel mode with the mains, all generator sets are connected to a <strong>common bus or bar<\/strong>. In turn, the generator sets are connected to each other by a <strong>communications cable (MSC Net).<\/strong><\/p>\n<p><strong>DSE 8620 MKII<\/strong> Features<\/p>\n<h3 style=\"padding-left: 40px;\">4. Generator set to mains stand by operation with uninterrupted return to the mains.<\/h3>\n<ul>\n<li><strong><u>With external switching<\/u><\/strong><\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4300 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/5_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"With external switching\" width=\"838\" height=\"355\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 838px; --smush-placeholder-aspect-ratio: 838\/355;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/5_a-single-generator-set-with-a-multitude-of-different-applications.jpg 838w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/5_a-single-generator-set-with-a-multitude-of-different-applications-300x127.jpg 300w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/5_a-single-generator-set-with-a-multitude-of-different-applications-768x325.jpg 768w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 838px) 100vw, 838px\"><\/p>\n<p>In this mode, the <strong>control unit <\/strong>of the generator set <strong>controls the external switching<\/strong>, detects when <strong>a failure occurs in the mains, and starts the engine<\/strong>. Once started, and while having all its parameters within the previously established limits, the control unit sends orders to <strong>open and shut <\/strong>the unit&rsquo;s external switching contactors and motorised thermal magnetic breakers (without mechanical interlock) respectively, so as to <strong>change the supply from the mains to the generator set<\/strong>. When the mains is <strong>restored<\/strong>, the control unit enables the <strong>change of supply from the generator set to the mains<\/strong>, thus enabling <strong>synchronism <\/strong>with the main network for a few seconds. The set gradually <strong>reduces the delivered load<\/strong>, and then <strong>opens the contactor or circuit breaker <\/strong>for Gen, and the <strong>engine stops <\/strong>after a period of <strong>cooling<\/strong>.<\/p>\n<ul>\n<li><strong><u>&lsquo;Half a commutation&rsquo;<\/u><\/strong><\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4301 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/6_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"Half a commutation\" width=\"838\" height=\"355\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 838px; --smush-placeholder-aspect-ratio: 838\/355;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/6_a-single-generator-set-with-a-multitude-of-different-applications.jpg 838w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/6_a-single-generator-set-with-a-multitude-of-different-applications-300x127.jpg 300w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/6_a-single-generator-set-with-a-multitude-of-different-applications-768x325.jpg 768w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 838px) 100vw, 838px\"><\/p>\n<p>The configuration above can be changed by programming the control unit so that the circuit magnetic breaker of the Gen set also functions as a Gen set switch. The external mains switch is controlled by the control unit of the generator set. In the event of a mains failure, the generator set behaves in the same way as with a complete switch.<\/p>\n<h3 style=\"padding-left: 40px;\">5. Generator set that export a fixed load to the mains with a stand-by function in case of mains failure.<\/h3>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4302 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/7_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"Generator set that export a fixed load to the mains with a stand-by function in case of mains failure.\" width=\"819\" height=\"566\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 819px; --smush-placeholder-aspect-ratio: 819\/566;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/7_a-single-generator-set-with-a-multitude-of-different-applications.jpg 819w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/7_a-single-generator-set-with-a-multitude-of-different-applications-300x207.jpg 300w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/7_a-single-generator-set-with-a-multitude-of-different-applications-768x531.jpg 768w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 819px) 100vw, 819px\"><\/p>\n<p>Several of the applications mentioned above can be combined. The<strong> selector <\/strong>in the <strong>\u00ab\u00a0Export\u00a0\u00bb <\/strong>position 0 work mode activates the generator set that <strong>exports to the mains <\/strong>a fixed amount of power according to the established schedule, the amount of power, and the supply time. Besides, it remains in a <strong>stand-by mode in case of mains failure. <\/strong>The <strong>fixed amount of power <\/strong>generated by the gen set (green area) and exported to the mains is established by a <strong>potentiometer<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4303 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/8_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"Diagram of an installation in which the generator set exports a fixed amount of power to the mains\" width=\"695\" height=\"350\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 695px; --smush-placeholder-aspect-ratio: 695\/350;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/8_a-single-generator-set-with-a-multitude-of-different-applications.jpg 695w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/8_a-single-generator-set-with-a-multitude-of-different-applications-300x151.jpg 300w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 695px) 100vw, 695px\"><\/p>\n<p><em><u>Note.-<\/u><\/em><em> The green area corresponds to the power supplied by the gen set and the blue area corresponds to the power supplied by the mains.<\/em><\/p>\n<h3 style=\"padding-left: 40px;\">6. Generator set in stand-by mode when the mains experience consumption peaks or a failure in the mains supply.<\/h3>\n<p>Another application of this equipment is the operation <strong>in support or stand-by mode to the mains<\/strong> for specific situations in which there is a consumption peak and the mains do not have enough supply capacity. In this case, put the selector in the <strong>\u00ab\u00a0Peak-Shaving\u00a0\u00bb <\/strong><u>position I mode.<\/u> In this position, the function of the potentiometer consists of setting the amount of power for activating the generator set to supply surplus power required by the load. Besides, it remains in a <strong>stand-by mode in case of mains failure<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4304 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/9_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"Diagram of an installation in which the generator set supplies the necessary power to the mains when there is a consumption peak\" width=\"889\" height=\"908\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 889px; --smush-placeholder-aspect-ratio: 889\/908;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/9_a-single-generator-set-with-a-multitude-of-different-applications.jpg 889w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/9_a-single-generator-set-with-a-multitude-of-different-applications-294x300.jpg 294w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/9_a-single-generator-set-with-a-multitude-of-different-applications-768x784.jpg 768w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 889px) 100vw, 889px\"><\/p>\n<p><em><u>Note.-<\/u><\/em><em> The green area corresponds to the power supplied by the gen set and the blue area corresponds to the power supplied by the mains.<\/em><\/p>\n<h2>GENERATOR SET OPERATION TESTS with load from an installation<\/h2>\n<p>In order to test the generator set operation in one of these installations, two operation modes have been established:<\/p>\n<ol>\n<li>By simulating a mains failure, the <strong>generator set <\/strong>is synchronised with the mains. They remain parallel for a few seconds and then, the gen set <strong>takes on the installation load during the test,<\/strong> disconnecting the mains.<\/li>\n<\/ol>\n<p>Therefore, put the <strong>TEST MODE <\/strong>selector in position <strong>I <\/strong>and the <strong>PARALLEL<\/strong> selector in position I.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4305 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/10_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"\" width=\"483\" height=\"194\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 483px; --smush-placeholder-aspect-ratio: 483\/194;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/10_a-single-generator-set-with-a-multitude-of-different-applications.jpg 483w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/10_a-single-generator-set-with-a-multitude-of-different-applications-300x120.jpg 300w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 483px) 100vw, 483px\"><\/p>\n<p>When <strong>the test is finished, <\/strong>the <strong>TEST MODE <\/strong>selector is put in the <strong>0 mode<\/strong> and the mains is automatically connected again, remaining in <strong>parallel <\/strong>with the gen set for a few seconds and taking on the installation load. The gen set reduces power supply until it stops, remaining again as a stand-by with the mains and\/or the feature that it had before the test.<\/p>\n<p style=\"padding-left: 40px;\">2. The generator set must be synchronised with the mains and work in parallel with it, <strong>exporting an <\/strong>\u00ab\u00a0artificial\u00a0\u00bb <strong>load selected by the potentiometer<\/strong>.<\/p>\n<p>Therefore, select the fixed amount of power for carrying out the test using the potentiometer, put the <strong>TEST MODE <\/strong>selector in position <strong>II <\/strong>and the <strong>PARALLEL <\/strong>selector in position I.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4306 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/11_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"\" width=\"819\" height=\"200\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 819px; --smush-placeholder-aspect-ratio: 819\/200;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/11_a-single-generator-set-with-a-multitude-of-different-applications.jpg 819w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/11_a-single-generator-set-with-a-multitude-of-different-applications-300x73.jpg 300w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/11_a-single-generator-set-with-a-multitude-of-different-applications-768x188.jpg 768w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 819px) 100vw, 819px\"><\/p>\n<p>When <strong>the test is finished,<\/strong> the <strong>TEST MODE <\/strong>selector is switched to the <strong>0 mode. <\/strong>The gen set reduces power supply until it stops, remaining again as a stand-by with the mains and\/or the feature it had before the test.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4307 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/12_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"\" width=\"643\" height=\"173\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 643px; --smush-placeholder-aspect-ratio: 643\/173;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/12_a-single-generator-set-with-a-multitude-of-different-applications.jpg 643w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/12_a-single-generator-set-with-a-multitude-of-different-applications-300x81.jpg 300w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 643px) 100vw, 643px\"><\/p>\n<p>The combination of two or more generator sets <strong><u>with this type of unit<\/u><\/strong> provides a number of <strong>sophisticated <\/strong>features such as:<\/p>\n<ul>\n<li>2 Gen sets in sets in Mutual Stand by with each other.<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4308 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/13_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"2 Gen sets in sets in Mutual Stand by with each other.\" width=\"697\" height=\"321\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 697px; --smush-placeholder-aspect-ratio: 697\/321;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/13_a-single-generator-set-with-a-multitude-of-different-applications.jpg 697w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/13_a-single-generator-set-with-a-multitude-of-different-applications-300x138.jpg 300w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 697px) 100vw, 697px\"><\/p>\n<ul>\n<li>2 Gen sets in sets in Mutual Stand by with each other, and both in stand-by with the mains.<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4309 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/14_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"2 Gen sets in sets in Mutual Stand by with each other, and both in stand-by with the mains\" width=\"750\" height=\"301\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 750px; --smush-placeholder-aspect-ratio: 750\/301;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/14_a-single-generator-set-with-a-multitude-of-different-applications.jpg 750w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/14_a-single-generator-set-with-a-multitude-of-different-applications-300x120.jpg 300w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 750px) 100vw, 750px\"><\/p>\n<ul>\n<li>Two or more generator sets in stand-by with the mains and in parallel with the mains.<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4310 lazyload\" data-src=\"\/wp-content\/uploads\/2020\/10\/15_a-single-generator-set-with-a-multitude-of-different-applications.jpg\" alt=\"\" width=\"750\" height=\"276\" title=\"\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 750px; --smush-placeholder-aspect-ratio: 750\/276;\" data-srcset=\"https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/15_a-single-generator-set-with-a-multitude-of-different-applications.jpg 750w, https:\/\/www.inmesol.com\/wp-content\/uploads\/2020\/10\/15_a-single-generator-set-with-a-multitude-of-different-applications-300x110.jpg 300w\" data-sizes=\"auto\" data-original-sizes=\"(max-width: 750px) 100vw, 750px\"><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The generator set that is used in rental, public services, construction or other applications, in which the gen set must perform multiple functions<\/p>\n","protected":false},"author":2,"featured_media":4295,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[33,37,39],"tags":[],"categorias-smart-power-":[],"paises-":[],"class_list":["post-4294","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ingles","category-corporative","category-news-generators-sets"],"_links":{"self":[{"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/posts\/4294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/comments?post=4294"}],"version-history":[{"count":0,"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/posts\/4294\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/"}],"wp:attachment":[{"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/media?parent=4294"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/categories?post=4294"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/tags?post=4294"},{"taxonomy":"categorias-smart-power-","embeddable":true,"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/categorias-smart-power-?post=4294"},{"taxonomy":"paises-","embeddable":true,"href":"https:\/\/www.inmesol.com\/fr\/wp-json\/wp\/v2\/paises-?post=4294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}